Bracket on the frame
The included bracket bolts to the machine frame or the old panel's enclosure; the device hangs where the operators already look.
An industrial touchscreen that boots straight into the operator panel you built in LK Go, the free app. Mount it on the machine with the included bracket, hand it to the operators, take it back when the new panel arrives. Between outages it logs history, draws dashboards and reads the ladder live.
One-time price, no subscription · ships within 8 weeks of order · full refund any time before your unit ships · 30-day money-back after delivery · invoice / PO instead of a card · try it in the live demo
Panels die once every few years. The rest of the time LK On (and LK Go on your phone) is the diagnostics tool you reach for first.
Pick the tags worth keeping and LK On logs them on change: trends, gauges, counters, uptime, error codes. The honest answer to "what changed since Friday?", with no SCADA project and no server.
Load the PLC's L5X on LK On and read the ladder with live values: which contact is open, which timer is counting, which rung is holding the start. Tap a tag, jump to its history. Alarm rules send to Telegram or WhatsApp, with a morning digest instead of a hundred pings.
The size that fits where the old panel was. Everything included: hardware, all software, updates, mounting bracket, power supply.
More room for dashboards and ladder side by side. Same software, same box contents, bigger screen.
| Full refund before shipping | Any time before your unit ships: one email, no questions, no restocking anything. |
|---|---|
| 30-day money-back after delivery | Not what your line needed? Send it back within 30 days of delivery, complete and undamaged, at your shipping cost, for a full refund. |
| One-year limited warranty | Defects in materials and workmanship, 12 months from delivery: repair or replace. Not liquid inside, drops, wrong voltage or an opened enclosure. |
| Ships within 8 weeks of order | The window is named here, not in an email later. If we miss it by more than 2 weeks, we email everyone and offer a refund. Shipping to an address in the United States is included. |
| No subscription | One price, everything included. Software updates included, with automatic rollback. |
| Not a certified HMI, not a safety device | A temporary bridge while the original panel is repaired or replaced — and a diagnostics tool between outages. |
The long form — payment, ship window, cancellation, the 30-day return, warranty — is in the preorder terms.
| Screen | 7″ IPS 1024×600, 400 cd/m², 5-point capacitive touch, 1 mm tempered glass · 10″ IPS 1280×800, 500 cd/m², 10-point capacitive touch, 1 mm armored glass Glove-friendly button sizes in the operator panel; readable from across the machine. |
|---|---|
| Network | 7″: 2× Gigabit Ethernet · 10″: 1× Gigabit Ethernet · Wi-Fi and Bluetooth on board The wired port talks to the PLC on the machine segment. Wi-Fi joins the plant network for the LK Go hand-off, optional alarm messages and updates; with no network at all the device raises its own setup hotspot. No cloud, no account. |
| Power | 7″: DC 9–30 V · 10″: DC 15–30 V, screw terminal 6 W typical / 11.4 W max (7″), 8.4 W typical / 13.3 W max (10″). Desktop power supply included; the cabinet's 24 V DC rail works too. |
| Ports | 7″: USB 3.0 + USB 2.0 type-A, USB-C, micro-HDMI out · 10″: 2× USB 3.0 type-A, USB-C, HDMI out USB for a keyboard during setup or a memory stick with the panel export. 2× RS-232, 2× RS-485, CAN FD and 8 GPIO on the back, not used by the software today. |
| Compute & storage | Quad-core 64-bit ARM, 8 GB RAM, 32 GB eMMC, TF-card slot History raw 30 days, hourly 1 year, daily 5 years fits on board. |
| Environment | 7″: −10 to +60 °C · 10″: −20 to +70 °C operating · fanless No moving parts; nothing to clog. |
| Size & weight | 7″: 188 × 123 × 33 mm, 0.7 kg · 10″: 275.5 × 193.5 × 46 mm, 1.3 kg Fits where a 7″ or 10″ panel sat, or on a bench beside it. |
| Mounting | Panel cutout or VESA holes + bracket in the box Onto the machine frame, a VESA arm on a post, or standing on the bench beside the dead panel. |
| Enclosure | Fanless industrial enclosure, IP65 front when panel-mounted; rear not rated Ratings and certifications are the enclosure manufacturer's, per its datasheet; LineKeeper adds none of its own. |
| Protocols | EtherNet/IP · SLC-500/MicroLogix · PowerFlex · Siemens S7 · Modbus TCP/RTU · OPC UA Allen-Bradley Logix tags discovered from the controller; SLC-500/MicroLogix over legacy PCCC (PLC-5 experimental); PowerFlex drives read-only; S7 and Modbus by address. S7-1200/1500: PUT/GET enabled and non-optimized DBs (a CPU access setting, not a program change). PLC program never modified. |
| Software | Panel · live tags · dashboards · history · ladder L5X ladder with live values. Updates in one tap with rollback. |
The included bracket bolts to the machine frame or the old panel's enclosure; the device hangs where the operators already look.
The rear VESA holes take any standard arm — eye level on a machine post, swung out of the way for the repair crew.
Nothing to drill: stand it beside the dead panel, plug in power and Ethernet, and the line is back under control.
Take it back when the panel returns. Unplug, keep it in the service kit. It stays useful — history, dashboards, live ladder for any machine on the network.
| LK Go + LK On | Wait for the replacement | A spare panel on the shelf | |
|---|---|---|---|
| Line running again | Minutes with a saved copy · about an hour without one | 2–6 weeks lead time + panel project rebuild; an integrator visit is days of waiting plus travel | Hours, if the spare is the right model and the project loads |
| Needs the original panel project | No, helps if you have it | Yes | Yes, and the software to load it |
| Needs a programmer | No for a saved copy · a phone call without one | Yes, for the panel project rebuild | Usually |
| Cost today | LK Go free · Pro $59.99 · LK On $800–900 | $1,500–$4,000 + programming + freight | A spare per panel model, sitting idle |
| Covers more than one machine | Yes, one kit, one profile per machine | No | Only machines with that exact panel |
| Useful between failures | Yes: dashboards, history, live ladder, alarms | No | No |
| Recurring fees | None | None | None |
No email required to see the result.
Pick a size, leave a contact. We hold your place in the first batch and email an invoice (NET-30 for plants) or the card link — nothing is charged until you decide, and a reservation is cancelled with one reply.
LK Go is the same idea on a phone: copy the panel's screen while it still works, run the machine from the phone the day it doesn't. When LK On arrives, the panel moves onto it in two taps.
First-batch units ship within 8 weeks of order. You get a tracking number by email the day yours leaves. If we miss the window by more than 2 weeks, we email everyone and offer a full refund.
Yes — a full refund at any time before your unit ships: one email, no questions. After delivery, you have 30 days to send it back — complete, undamaged, shipping at your cost — for a full refund. The preorder terms spell it out.
One year from delivery against defects in materials and workmanship: we repair or replace the unit and ship it back to you. You ship it to us. Like every hardware maker, we don't cover what the unit didn't do to itself: liquid or chips inside, a drop, a cracked screen, the wrong supply voltage, an opened enclosure. The full list is in the warranty terms.
The device with the software installed, a DC power supply, a mounting bracket (VESA or panel mount), an Ethernet cable and a one-page recovery guide written for line staff.
Allen-Bradley ControlLogix and CompactLogix over EtherNet/IP (tags, UDTs, arrays, timers, counters and I/O modules discovered automatically), SLC-500 and MicroLogix over legacy PCCC (PLC-5 experimental), PowerFlex drives (read-only), Siemens S7, Modbus TCP/RTU and OPC UA. S7-1200/1500 need PUT/GET enabled and non-optimized DBs (a CPU access setting, not a program change). The PLC program is never modified.
No. LK On is not a certified HMI and not a safety device. It is a temporary bridge while the original panel is repaired or replaced, and a diagnostics tool afterwards. The PLC's own safety program stays in charge; never use it for safety functions.
Yes. Reserve a unit, mention the PO, and we send an invoice — NET-30 for plants. Card payment on the site goes through Stripe; the shipping address is collected there.
No. One price, everything included: hardware, all software features, software updates with automatic rollback. Nothing per tag, per seat or per month.
LK Go finds the device on the network and copies your panels and dashboards onto it in two taps — and back. Build the screen today in LK Go, the free app; it moves onto the device when it arrives.
Yes. Each machine gets its own profile (PLC address, panel, dashboards, history) and you switch between them on the device. Only one machine is connected at a time, so a second unit is for the day two panels die at once, or when one unit is going to live on a machine for weeks.
No. Everything (live view, control panel, logging, dashboards, ladder) runs on the device itself. Internet is only needed for alarm messages, optional remote access and software updates.
Not yet. LK Up, our free maintenance system, is in early access; the plan is for LK On's diagnostic episodes to become incidents on the right asset there. LK Up does not need LK On, and LK On does not need LK Up.
Yes. One device holds a profile per machine, LK Go exports your exact screens as a file, writes stay locked until the plant unlocks the tags you name, and remote access is per person and revocable. How the support call goes, and what we build for integrators, is on the integrator page. Need a driver, report or export your customers ask for? Tell us — integrator requests reach the developer directly.